Balony Kubicek Spol Sro BB70Z N245DK accident near Park City, Utah

Apr 22, 2017 · NTSB number GAA17CA262 · Final report

Probable cause

The pilot’s failure to see and avoid power lines during landing.

NTSB analysis

The pilot reported that the wind shifted before departure and that, although this would result in the balloon travelling to an area with "limited landing opportunities," he chose to continue the departure. During landing, the balloon descended to about 20 to 30 ft above the ground, and the landing area was on a hillside that had a commercial building on the top and that, at the base of the hill, was a short pole with guy wires. He did not see any other poles, so he "focused" on the intended landing site. As the balloon approached the landing site, a passenger asked, "if we would hit that power line?" He looked up and saw two power lines above and forward of the balloon's path, and he immediately vented the balloon to land and stop its forward progress. The balloon collided with the power lines and settled to the ground.

The balloon sustained substantial damage to 3 of its 24 cables that attach the envelope to the basket.

The pilot reported that there were no preaccident mechanical failures or malfunctions with the balloon that would have precluded normal operation.

Text from the NTSB. Open the NTSB docket for GAA17CA262 for the full record.

Event

Date
Apr 22, 2017
Type
Accident
Place
Park City, Utah
Highest injury
None
Weather
Visual (VMC)
Light
Day

Balony Kubicek Spol Sro BB70Z

N-number
N245DK
Category
Balloon
Year built
2011
Damage
Substantial
Operating rule
Part 91 (general aviation)
Purpose of flight
Business

From the NTSB aviation accident database: N-registered aircraft, events since 2008, data through Oct 28, 2026. The file is published monthly, so the latest weeks are incomplete and recent records can change. The official source is the NTSB aviation investigation search. CheckAero is independent and not affiliated with the NTSB.